SignalLogFaultMaskTrigger Parameter
Default Value: 12983363
Minimum Value: None
Maximum Value: None
Units: None
Type: int
IMPORTANT: The controller generates an axis fault only if you set the corresponding bit in the FaultMask Parameter. When an axis fault is generated, you can configure what the axis does by changing the state of the corresponding bit in the FaultMaskDecel Parameter, the FaultMaskDisable Parameter, and the FaultMaskDisableDelay Parameter.
Use the SignalLogFaultMaskTrigger parameter to specify the fault conditions that trigger Signal Log. This parameter is a bit mask where each bit applies to a specific axis fault.
Signal Log is triggered when the controller generates an axis fault from the SignalLogFaultMaskTrigger parameter on an axis that you specify for the SignalLogAxes Parameter.