PrimaryBissEncoderTurns Parameter
Default Value: 1
Minimum Value: 1
Maximum Value: 4096
Units: Turns
Type: int
HARDWARE: This parameter applies only to the drives and configurations that follow:
Table: Applicable Drive Types and Feedback Options
Drive Type | Feedback Option |
---|---|
FLEX | Using a BiSS absolute encoder |
SI4 | Using a BiSS absolute encoder with the -A1 absolute encoder option |
iXA4 | Using a BiSS absolute encoder |
XA4 | Using a BiSS absolute encoder |
iXC2 | Using a BiSS absolute encoder |
XC2 | Using a BiSS absolute encoder |
iXC2e | Using a BiSS absolute encoder |
XC2e | Using a BiSS absolute encoder |
iXC4 | Using a BiSS absolute encoder |
XC4 | Using a BiSS absolute encoder |
iXC4e | Using a BiSS absolute encoder |
XC4e | Using a BiSS absolute encoder |
iXC6e | Using a BiSS absolute encoder |
XC6e | Using a BiSS absolute encoder |
iXI4 | Using |
XI4 | Using |
iXL2e | Using a BiSS absolute encoder |
XL2e | Using a BiSS absolute encoder |
iXL5e | Using a BiSS absolute encoder |
XL5e | Using a BiSS absolute encoder |
iXR3 | Using a BiSS absolute encoder |
XR3 | Using a BiSS absolute encoder |
Use the PrimaryBissEncoderTurns parameter to specify the number of turns for the absolute position part of the BiSS encoder. Get the number of turns from the encoder data sheet. Set this parameter to a value greater than 1 for a multi-turn absolute encoder. The information supplied by this parameter and by the PrimaryBissEncoderResolution Parameter is used to configure the serial communication interface to the BiSS encoder.