PrimaryBissEncoderIncrementalResolution Parameter
Default Value: 512
Minimum Value: 16
Maximum Value: None
Units: None
Type: int
This parameter applies only to the drives and configurations that follow:
Table: Applicable Drive Types and Feedback Options
Drive Type | Feedback Option |
---|---|
FLEX | Using a BiSS absolute encoder |
SI4 | Using a BiSS absolute encoder with the -A1 absolute encoder option |
iXA4 | Using a BiSS absolute encoder |
XA4 | Using a BiSS absolute encoder |
iXC2 | Using a BiSS absolute encoder |
XC2 | Using a BiSS absolute encoder |
iXC2e | Using a BiSS absolute encoder |
XC2e | Using a BiSS absolute encoder |
iXC4 | Using a BiSS absolute encoder |
XC4 | Using a BiSS absolute encoder |
iXC4e | Using a BiSS absolute encoder |
XC4e | Using a BiSS absolute encoder |
iXC6e | Using a BiSS absolute encoder |
XC6e | Using a BiSS absolute encoder |
iXI4 | Using |
XI4 | Using |
iXL2e | Using a BiSS absolute encoder |
XL2e | Using a BiSS absolute encoder |
iXL5e | Using a BiSS absolute encoder |
XL5e | Using a BiSS absolute encoder |
iXR3 | Using a BiSS absolute encoder |
XR3 | Using a BiSS absolute encoder |
Use the PrimaryBissEncoderIncrementalResolution parameter to specify the resolution of the incremental feedback signals you receive from the BiSS encoder. You can get the incremental line count or period from the encoder data sheet. For rotary encoders, you must specify the resolution in units of lines per revolution. For linear encoders, you must specify the resolution to the ratio of the incremental period to the absolute period.