MotorSupplyFaultTime Parameter

Default Value: 20

Minimum Value: 0

Maximum Value: 1000

Units: time milliseconds

Type: int

IMPORTANT: This parameter applies only to drives with an AC motor supply input, including the FLEX, iXA4, XA4, iXC4, XC4, iXC4e, XC4e, iXC6e, XC6e, iXL5e, XL5e, iXR3, and XR3. On the FLEX, iXA4, and XA4, the parameter value from the first axis is used by the drive.

Use the MotorSupplyFaultTime parameter to specify the time interval for which to ignore a motor supply fault. A motor supply fault is generated when there is a loss of power to the motor supply input of the drive for a time interval longer than the MotorSupplyFaultTime parameter.

If you set this parameter to 0, there will be no delay between a loss of motor supply and a motor supply fault. The default parameter value is set to 20 milliseconds, which lets the drive ignore a loss of motor supply for a single AC cycle at both 50 and 60 Hz.