IfovConfigurations Parameter

Default Value: 0

Minimum Value: 0

Maximum Value: 2

Units: None

Type: int

IMPORTANT: You must reset the controller for these changes to have an effect. If you set the IfovConfigurations parameter in an AeroScript program, this does not set the active value and does not have an effect on program execution.

Before you can use IFOV, you must set the IfovConfigurations parameter to the number of configurations for which memory is reserved during initialization. This parameter uses the values that follow:

  • A value of 0 is the default and allocates no memory for IFOV. This prevents IFOV from running on the controller.
  • A value of 1 allocates memory for one IFOV configuration. This is the typical number of supported configurations.
  • A value of 2 allocates memory for two IFOV configurations. This is the maximum number of supported configurations.

On each task, you can specify a different IFOV configuration. But you can enable IFOV only on two tasks at the same time.