FeedholdInput Parameter

Default Value: 0

Minimum Value: 0

Maximum Value: None

Units: None

Type: int

The FeedholdInput parameter specifies a digital binary input that the controller uses as a feedhold input for the selected task. When you set this parameter to a valid digital binary input and the input is triggered, the feedhold state of the task is toggled.

Table: Feedhold Inputs and Descriptions

Setting

Description

Input Type

This setting specifies the input type that is used. Select an input type based on your system configuration:

  • Disabled is the default. No input type is selected (no digital input is assigned).
  • Drive Digital: The button is connected to an input on a drive.
  • Virtual Binary: This is a general-purpose register. To set this register from a program, use the VirtualBinaryInputSet() function. If you are using an Ethernet I/O module connected to the PC for this input, then you must select this option and write this value in a task program.

Axis Index

This setting specifies which axis is used for input. The default axis is 0 (typically Axis X). This setting does not apply if you select Virtual Binary as the Input Type.

Input Number

This setting specifies which input is used. The input number is zero-based. The default value is input zero.