FaultAnalogOutputSetup Parameter

Default Value: 0

Minimum Value: None

Maximum Value: None

Units: None

Type: int

IMPORTANT: The controller sets analog outputs on a fault condition only for faults that you select in the FaultMaskOutput Parameter.

The FaultAnalogOutputSetup parameter specifies one or more analog outputs that the axis changes when it is in a fault condition. This parameter is bitmapped, where each bit corresponds to one drive output. When you select the box for an output, the axis sets that output to the value that is specified by the corresponding FaultAnalogOutput#Value parameter (which includes FaultAnalogOutput0Value through FaultAnalogOutput5Value).

The I/O mapping of your drive can limit how you configure analog outputs on a fault condition. For information about how I/O is mapped to different drive types, see I/O Functions.