DefaultSpindleSpeed Parameter
Default Value: 360
Minimum Value: 0.0
Maximum Value: None
Units: dependent velocity
Type: double
The DefaultSpindleSpeed parameter specifies the rotation speed of the spindle for the selected task. Each time you reset the controller, the controller uses the rotation speed that you specified for this parameter. This parameter initializes the value that is specified by the spindle of the current task of the S function.
Do not try to set the active value with this parameter. To set the active value for the speed of the spindle of the current task from within an AeroScript program, use the S Function.
IMPORTANT: You must reset the controller for these changes to have an effect.