AuxiliaryBissEncoderResolution Parameter
Default Value: 32
Minimum Value: 1
Maximum Value: 56
Units: bit
Type: int
HARDWARE: This parameter applies only to the drives and configurations that follow:
Table: Applicable Drive Types and Feedback Options
Drive Type | Feedback Option |
---|---|
FLEX | Using a BiSS absolute encoder |
iXC4 | Using a BiSS absolute encoder |
XC4 | Using a BiSS absolute encoder |
iXC4e | Using a BiSS absolute encoder |
XC4e | Using a BiSS absolute encoder |
iXC6e | Using a BiSS absolute encoder |
XC6e | Using a BiSS absolute encoder |
iXL2e | Using a BiSS absolute encoder |
XL2e | Using a BiSS absolute encoder |
iXL5e | Using a BiSS absolute encoder |
XL5e | Using a BiSS absolute encoder |
iXR3 | Using a BiSS absolute encoder |
XR3 | Using a BiSS absolute encoder |
Use the AuxiliaryBissEncoderResolution axis parameter to specify the number of bits of resolution for the absolute position information from the BiSS encoder. Obtain the number of bits of resolution from the encoder data sheet. This information is used to configure the serial communication interface to the BiSS encoder. For a multi-turn absolute encoder, you also should set the AuxiliaryBissEncoderTurns Parameter, which increases the resolution of the serial communication.