Analog2InputOffset Parameter
Default Value: 0.0
Minimum Value: -1000.0
Maximum Value: 1000.0
Units: volts millivolts
Type: float
Tip: In the Analog Input Filters section of I/O in Studio, click View Coefficients to see the analog input filter coefficient parameters and their setup parameter. To see only the summary of filter specifications, click View Filters.
Aerotech does offset calibration of all analog inputs at the factory. In most production environments, you can keep this parameter set to the default value of 0.
The Analog2InputOffset parameter specifies a user-defined offset that is applied to the analog input. The controller adds the value that is specified for this parameter to the value that is read from the analog input hardware. The offset is applied to all uses the analog input.