PrimaryBissEncoderTurns Parameter

Default Value: 1

Minimum Value: 1

Maximum Value: 4096

Units: Turns

Type: int

HARDWARE: This parameter applies only to the drives and configurations that follow:

Table: Applicable Drive Types and Feedback Options

Drive Type Feedback Option
FLEX Using a BiSS absolute encoder
SI4 Using a BiSS absolute encoder with the -A1 absolute encoder option
iXA4 Using a BiSS absolute encoder
XA4 Using a BiSS absolute encoder
iXC2 Using a BiSS absolute encoder
XC2 Using a BiSS absolute encoder
iXC2e Using a BiSS absolute encoder
XC2e Using a BiSS absolute encoder
iXC4 Using a BiSS absolute encoder
XC4 Using a BiSS absolute encoder
iXC4e Using a BiSS absolute encoder
XC4e Using a BiSS absolute encoder
iXC6e Using a BiSS absolute encoder
XC6e Using a BiSS absolute encoder
iXI4 Using a BiSS absolute encoder with the -A1 absolute encoder option
XI4 Using a BiSS absolute encoder with the -A1 absolute encoder option
iXL2e Using a BiSS absolute encoder
XL2e Using a BiSS absolute encoder
iXL5e Using a BiSS absolute encoder
XL5e Using a BiSS absolute encoder
iXR3 Using a BiSS absolute encoder
XR3 Using a BiSS absolute encoder

Use the PrimaryBissEncoderTurns parameter to specify the number of turns for the absolute position part of the BiSS encoder. Get the number of turns from the encoder data sheet. Set this parameter to a value greater than 1 for a multi-turn absolute encoder. The information supplied by this parameter and by the PrimaryBissEncoderResolution Parameter is used to configure the serial communication interface to the BiSS encoder.