Mechanical Specifications

Mounting and Cooling

The drive rack must be installed in an enclosed control cabinet suitable for installation of power equipment. A minimum enclosure rating of IP54 is required to comply with safety standards. Make sure that there is sufficient clearance surrounding the drive rack for free airflow and for the routing of cables and connections. Consideration for items such as line reactors, line filters, and motor chokes or inductance should be made during the initial cabinet design phase.

External cooling and Fan Tray cooling options require airflow clearance above and below the drive chassis. Refer to Cooling Options [-C0/-C1/-C2 Option].

Table: Mounting Specifications

 

iXR3/XR3

Customer-Supplied Enclosure IP54 Compliant

Weight

25 kg

Dimensions Refer to Dimensions
Minimum Clearance Airflow ~25 mm
Connectors ~100 mm
Operating Temperature Refer to Environmental Specifications
Drive IP Rating IP20

WARNING: Heavy Object

  1. Use a cart to move the product.
  2. To avoid injury, use two or more people to move and install this product.
  3. Lift this product only by the base. Do not use the cables or the connectors to lift or move this product.
  4. Do not use the handles on the front of the product to lift or move this product. Use the handles only to slide the product in and out of its enclosure.

Dimensions

IMPORTANT: iXR3 and XR3 dimensions are the same. iXR3 is shown.

Figure: Dimensions with Chassis Slides

IMPORTANT: iXR3 and XR3 dimensions are the same. iXR3 is shown.

Figure: Dimensions without Chassis Slides