Motor Power Output Connector

DANGER: Before you do maintenance to the equipment, disconnect the electrical power. Wait at least one (1) minute after removing the power supply before doing maintenance or an inspection. Otherwise, there is the danger of electric shock.

The drive can be used to drive the following motor types:

For a complete list of electrical specifications, refer to Electrical Specifications.

DANGER: Shock and Fire Hazard

Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.

The 7-pin terminal block style motor output connector is located on the front panel.

Table: Motor Power Output Connector Pinout

Pin

Description

Connector

Earth Ground to Motor

A

Brushless Phase A Motor Lead

DC Brush +

Stepper

B

Brushless Phase B Motor Lead

Stepper

C

Brushless Phase C Motor Lead

DC Brush -

Stepper Return

Table: Motor Power Output Mating Connector Ratings

Specification Description
Type 7-Pin Terminal Block
Part Numbers Aerotech: ECK02457
Phoenix: 1839678

Conductor Cross Section

One conductor, stranded with ferrule and plastic sleeve 18...22 AWG (0.25...0.75 mm2)
Two conductors (same cross-section), stranded , twin ferrule with plastic sleeve 20 AWG (0.5 mm2)
Tightening Torque 0.22...0.25 N·m
Conductor Insulation Strip Length 7 mm (0.25 in)

(1) Refer to the manufacturer website for additional information.