Motor Power Output Connectors

DANGER: Before you do maintenance to the equipment, disconnect the electrical power. Wait at least ten (10) minutes after removing the power supply before doing maintenance or an inspection. Otherwise, there is the danger of electric shock.

The drive can be used to drive the following motor types:

For a complete list of electrical specifications, refer to Electrical Specifications.

DANGER: Shock and Fire Hazard

Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.

Table: Motor Power Output Connector Pinout

Pin

Description

Connector

Motor Ground

A

Motor Phase A Output

B

Motor Phase B Output
C Motor Phase C Output

Table: Motor Power Output Mating Connector Ratings

Specification Description
Type 4-Pin Terminal Block
Part Numbers Aerotech: ECK02593
Phoenix: 1756298

Conductor Cross Section

One conductor, stranded with ferrule and plastic sleeve 14...22 AWG (0.25...2.5 mm2)
Two conductors (same cross-section), stranded, twin ferrule with plastic sleeve 16...20 AWG (0.5...1.5 mm2)
Tightening Torque 0.5...0.6 N·m
Conductor Insulation Strip Length 7 mm (0.25 in)

(1) Refer to the manufacturer website for additional information.

(2) Motor wires should be sized based on the motor supply input fuse value. Upstream fusing and/or circuit breakers can be used for additional protection.