Motor Supply Connector

DANGER: Shock and Fire Hazard!

Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.

IMPORTANT: To operate correctly, this product must have a power supply connected to the Motor Supply and a power supply connected to the Control Supply.

Motor power is applied to the GL4 at the four terminals of the Motor Supply connector. The DC+ input and the DC- input are connected to fuses inside the drive. Refer to Power Board Fuse Specifications for fuse values and part numbers.

DANGER: Shock Hazard! To prevent the risk of electric shock, do not operate the GL4 without a ground connection.

Figure: Motor Supply Connections

Table: Motor Supply Connector Pinout

Pin

Description

DC+ +40 VDC Input Range
RET Return for DC Input
DC- -40 VDC Input Range

Protective Ground - 2.5 mm2 / 14 AWG min conductor size

(1)The wire insulation is rated for 300 V.

Table: Motor Supply Mating Connector Ratings

Specification Description
Type 4-Pin Terminal Block
Part Numbers Aerotech: ECK02407
Phoenix: 1758843

Conductor Cross Section

One conductor, stranded with ferrule and plastic sleeve 14...22 AWG (0.25...2.5 mm2)
Two conductors (same cross-section), stranded, twin ferrule with plastic sleeve 16...20 AWG (0.5...1.5 mm2)
Tightening Torque 0.5...0.6 N·m
Conductor Insulation Strip Length 7 mm (0.25 in)

(1) Refer to the manufacturer website for additional information.