SignalLogPointsAfterTrigger Parameter
Default Value: 2000
Minimum Value: 100
Maximum Value: None
Units: points
Type: int
IMPORTANT: You must reset the controller for these changes to have an effect. If you set this parameter from an AeroScript program, the controller does not set the active value and this parameter does not have an effect on program execution.
Use the SignalLogPointsAfterTrigger parameter to specify the number of points that Signal Log collects after it is triggered.
When Signal Log is triggered, Signal Log collects the number of points that you specify for this parameter before it writes the data to a file on the file system. This lets you collect data after the trigger event occurs.