DataCollectionPoints Parameter
Default Value: 70000
Minimum Value: 100
Maximum Value: None
Units: points
Type: int
IMPORTANT: You must reset the controller for these changes to have an effect. If you set this parameter from an AeroScript program, the controller does not set the active value and this parameter does not have an effect on program execution.
The DataCollectionPoints parameter specifies the number of data collection points for which memory is reserved during initialization. The controller multiplies the value of the DataCollectionPoints parameter by the value of the DataCollectionItems parameter to calculate the total quantity of memory to allocate for data collection.
This parameter requires memory allocation. If the memory allocation does not complete correctly, a memory allocation error occurs. If memory resources are low, you can decrease the value of this parameter to release memory for other Automation1 features.