SignalLogFaultMaskTrigger Parameter

Default Value: 12983363

Minimum Value: None

Maximum Value: None

Units: None

Type: int

IMPORTANT: The controller generates an axis fault only if you set the corresponding bit in the FaultMask Parameter. When an axis fault is generated, you can configure what the axis does by changing the state of the corresponding bit in the FaultMaskDecel Parameter, the FaultMaskDisable Parameter, and the FaultMaskDisableDelay Parameter.

Use the SignalLogFaultMaskTrigger parameter to specify the fault conditions that trigger Signal Log. This parameter is a bit mask where each bit applies to a specific axis fault.

Signal Log is triggered when the controller generates an axis fault from the SignalLogFaultMaskTrigger parameter on an axis that you specify for the SignalLogAxes Parameter.