MfoAnalogInput Parameter

Default Value: 0

Minimum Value: 0

Maximum Value: None

Units: None

Type: int

The MfoAnalogInput parameter specifies the analog input channel that is used to automatically update the value of the MFO setting. A value of None disables the analog MFO input. But, when you set this parameter to a valid analog input, the MFO setting is automatically updated.

When under control of the MfoAnalogInput, the MFO setting is limited between the values of the MfoMinimum Parameter and the MfoMaximum Parameter and is rounded to the nearest MfoAnalogStep Parameter value. The analog input is scaled such that MfoAnalogMinVoltage Parameter maps to MfoMinimum parameter and MfoAnalogMaxVoltage Parameter maps to MfoMaximum parameter. If the value of the MfoAnalogStep parameter is zero, the MFO value is not rounded.

IMPORTANT: The MFO value does not change if the MfoLock task mode is active. For information, refer to the M48 command in G-Code Programming.