Fuse Specifications
WARNING: Replace fuses only with the same type and value.
Always disconnect the Mains power connection before you open the chassis. Fuses must not be changed with Mains power applied to the unit.
The fuses on the drive interface board are factory-configured based on the bus voltage configuration that you ordered. The fuses are not likely to blow under normal operating conditions.
The most likely reason for a fuse to blow is if you have connected the unit to the wrong AC line voltage.
Table: Drive Interface Board Motor Power Fuse Replacement Part Numbers
Bus |
Fuse |
Description |
Aerotech P/N |
Manufacturer P/N |
---|---|---|---|---|
Bus 1 |
F1 (-VB1 to -VB2) |
2 A SLO BLO, 3AG |
EIF00102 |
Littelfuse 313002 |
F1 (-VB3 to -VB5) |
3 A SLO BLO, 3AG |
EIF00103 |
Littelfuse 313003 |
|
F1 (-VB7 to -VB8) |
Not Used |
-- |
-- |
|
F2 (-VB1 to -VB5) |
4 A SLO BLO, 3AG |
EIF00104 |
Littelfuse 313004 |
|
F2 (-VB7 to -VB8) |
7 A SLO BLO, 3AG |
EIF00107 |
Littelfuse 313007 |
|
Bus 2 |
F3 (-VB1 to -VB2) |
2 A SLO BLO, 3AG |
EIF00102 |
Littelfuse 313002 |
F3 (-VB3 to -VB5) |
3 A SLO BLO, 3AG |
EIF00103 |
Littelfuse 313003 |
|
F3 (-VB7 to -VB8) |
Not Used |
-- |
-- |
|
F4 (-VB1 to -VB5) |
4 A SLO BLO, 3AG |
EIF00104 |
Littelfuse 313004 |
|
F4 (-VB7 to -VB8) |
7 A SLO BLO, 3AG |
EIF00107 |
Littelfuse 313007 |
IMPORTANT: Due to inrush currents, these fuses must be of the Slow Blow type.