High-Speed Inputs

High-speed inputs 20 and 21 can be used as general purpose inputs or as the trigger signal for high speed data collection. Refer to the DriveDataCaptureConfigureTrigger() function topic in Automation1 Help for more information.

You can use the external PSO synchronization functions to synchronize waveform generation with an external synchronization signal. When you activate this feature, the PSO Waveform module will not generate the configured waveform when an output event is received until the rising edge of the synchronization signal occurs. Refer to the PSO Waveform Functions in Automation1 Help.

Table: High-Speed Input Specifications

Specification

Value

Input Voltage

5V - 24 V input voltages

Input Current

10 mA

Input Device

HCPL-0630

Delay

50 nsec

Table: High-Speed Input Pins on the Auxiliary I/O Connector

Pin#

Description

In/Out/Bi

3

High-Speed Input 20 + / PSO External Sync. +

Input

4

High-Speed Input 20 - / PSO External Sync. -

Input

5

High-Speed Input 21 +

Input

6

High-Speed Input 21 -

Input

Figure: High-Speed Inputs