Control Supply Connector
DANGER: Shock and Fire Hazard
Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.
The Control Supply input supplies power to the communications and logic circuitry of the drive . The +24V input is connected to an internal fuse. Refer to Control Board Fuse Specifications for the internal fuse value and part number. For an isolated DC supply, connect 0V to protective ground at the supply. Use twisted pair wiring to minimize radiated noise emissions (refer to Control Supply Connections).
Refer to System Interconnection for additional information.
Figure: Control Supply Connections
Table: Control Supply Connector Pinout
Pin | Description |
---|---|
+24 V |
24 VDC (±10%) Control Power Input (2 A max, 0.75 A typical without brake) |
0 V |
Control Power Common Input |
|
Protective Ground |
Table: Control Supply Mating Connector Ratings
Specification | Description | |
---|---|---|
Type | 3-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02456 | |
Phoenix: 1839610 | ||
Conductor Cross Section |
One conductor, stranded with ferrule and plastic sleeve | 18...22 AWG (0.25...0.75 mm2) |
Two conductors (same cross-section), stranded , twin ferrule with plastic sleeve | 20 AWG (0.5 mm2) | |
Tightening Torque | 0.22...0.25 N·m | |
Conductor Insulation Strip Length | 7 mm (0.25 in) | |
(1) Refer to the manufacturer website for additional information. |