Current Command Output Signals

The iXI4/XI4 uses the Current Command A and B outputs to interface to an industry standard analog transconductance amplifier. These outputs are updated at a 20 kHz rate. Use the ServoLoopSetup parameter to configure this output type.

Table 2-5:     Current Command Pins on the Axis Connector

Pin #

Description

In/Out/Bi

1

Current Command A

Output

3

Signal Common

Output

14

Current Command B

Output

Table 2-6:     Current Command Signal Output Specifications

Specification

Value

Rated Output Current

10 mA

Output Voltage Range ±10 V

Reset State

0 V

Figure 2-2:     Current Command Output Schematic