Electrical Specifications

Table: Electrical Specifications (Common)

Description

Specification

Control Supply

Input Voltage

100-240 VAC (±10%)

Input Frequency

50-60 Hz

Inrush Current

120 APK @ 240 V

Input Current

0.7 ARMS

Internal Fuse 2 A/250 V, 35 A interrupt rating, L terminal only
SCCR Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes, 240 V (-240V1 option) or 480 V (-480V1/-480V2 option) maximum.
Power Amplifier Bandwidth 2500 Hz maximum (software selectable)
PWM Switching Frequency 20 kHz or 10 kHz (software selectable)
Minimum Load Inductance 0.5 mH
User Power Supply Output 5 VDC (@ 500 mA)
Motor Type Brushless
Protective Features
  • Output short circuit
  • Peak over current
  • DC bus over voltage
  • Motor RMS over current
  • Motor over temperature
  • Heatsink over temperature
  • Control power supply under voltage
  • IGBT supply under voltage
  • Shunt resistor monitoring
Insulation Over Voltage Category 3
Conductors Copper Only, 75 °C (1)

(1) The wire temperature rating could be higher than 75 °C. The 75 °C reference is for end-use installers when sizing the conductors per NFPA 70 NEC (National Electrical Code) where applicable.

Table: Electrical Specifications (by Ordering Option)

Input Voltage Option -240V1 -480V2 -480V1
Output Current Option -50 -100 -10 -20 -30 -50 -100

Motor Supply Input Current
(at full output power)

20 A 30 A 6 A 10 A 15 A 24 A 30 A

Motor Supply Maximum overload protection breaker

30 A 30 A

Motor Supply Input Voltage Max (1,2)
(Vrms phase to phase, +10%)

208-240 VAC
50/60 Hz

480Y/277 VAC(3)
50/60 Hz

Output Current (peak) (4) 50 A 100 A 10 A 20 A 30 A 50 A 100 A
Output Current (continuous)(4,5) 17.7 ARMS 35.4 ARMS 3.5 ARMS 7.1 ARMS 10.6 ARMS 17.7 ARMS

21.1 ARMS(6)

35.4 ARMS(7)

Peak Output Voltage 340 V   390 V
MOTOR: Electronic Overcurrent Shutoff 100 A 200 A 100 A 100 A 100 A 200 A 200 A

SHUNT: Electronic
Overcurrent Shutoff

50 A 100 A 50 A 50 A 50 A 100 A 100 A
Internal Motor Supply Capacitance 4800 µF 1500 µF
Capacitor Safe Discharge Time 10 minutes (verify <50 VDC at DC bus terminals)

(1) TN configuration only.

(2) The iXC6e/XC6e requires three phase motor supply power.

(3) The XC6-480V1 or -480V2 drive must be connected only to a grounded wye-source where the maximum voltage does not exceed 277 VAC to ground.

(4) There are three motor output phases from the drive.

(5) These values are under full output power. Under a lighter load, the continuous output current capability will be higher.

(6) Specification for 20 kHz PWM switching frequency.

(7) Specification for 10 kHz PWM switching frequency.

Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.

WARNING: Electric Shock or Fire Hazard! A fault current interruption could be the result of an open branch-circuit protective device. To reduce the risk of fire or electric shock, examine the current-carrying parts and other controller components. Replace all damaged parts. If a burnout of the current element of an overload relay occurs, you must replace the complete overload relay.

AVERTISSEMENT : Risque d'électrocution ou d'incendie ! Une interruption du courant de défaut peut être provoqué par un dispositif de protection de circuit de dérivation ouvert. Pour réduire le risque d'incendie ou d'électrocution, examinez les pièces conductrices de courant et les autres composants du contrôleur. Remplacer toutes les parties endommagées. Si un grillage de l'élément de courant d'un relais de surcharge se produit, vous devez remplacer le relais de surcharge dans son ensemble.