Maintenance

IMPORTANT: For your own safety and for the safety of the equipment:

  • Do not remove the cover of the iXC4e/XC4e.
  • Do not attempt to access the internal components.

A fuse that needs to be replaced indicates that there is a more serious problem with the system or setup. Contact Global Technical Support for assistance.

DANGER: If you must remove the covers and access any internal components be aware of the risk of electric shock.

  1. Disconnect the Mains power connection.
  2. Wait at least ten (10) minutes after removing the power supply before doing maintenance or an inspection. Otherwise, there is the danger of electric shock.
  3. All tests must be done by an approved service technician. Voltages inside the controller and at the input and output power connections can kill you.

Table 5-1:     LED Description

LED

Color

Description

PWR

GREEN

The axis is powered on.

RED(1) The light will turn red when power is first applied, a communication problem occurs, or a drive reset is initiated. It will remain red during drive initialization.

EN/FLT

GREEN

The axis is Enabled.

RED The axis is in a Fault Condition.
GREEN/RED (alternates)

The axis is Enabled in a Fault Condition.

or

The light is configured to blink for setup.

(1) Red PWR LED functionality is only present on some versions of the drive.

Table 5-2:     Troubleshooting

Symptom

Possible Cause and Solution

No Communication

Make sure the power LED is illuminated (this indicates that power is present).

Make sure that all communication cables (HyperWire, for example) are fully inserted in their ports.