Maintenance
IMPORTANT: For your own safety and for the safety of the equipment:
- Do not remove the cover of the iXC4e/XC4e.
- Do not attempt to access the internal components.
A fuse that needs to be replaced indicates that there is a more serious problem with the system or setup. Contact Global Technical Support for assistance.
DANGER: If you must remove the covers and access any internal components be aware of the risk of electric shock.
- Disconnect the Mains power connection.
- Wait at least ten (10) minutes after removing the power supply before doing maintenance or an inspection. Otherwise, there is the danger of electric shock.
- All tests must be done by an approved service technician. Voltages inside the controller and at the input and output power connections can kill you.
|
LED |
Color |
Description |
|---|---|---|
|
PWR |
GREEN |
The axis is powered on. |
| RED(1) | The light will turn red when power is first applied, a communication problem occurs, or a drive reset is initiated. It will remain red during drive initialization. | |
|
EN/FLT |
GREEN |
The axis is Enabled. |
| RED | The axis is in a Fault Condition. | |
| GREEN/RED (alternates) |
The axis is Enabled in a Fault Condition. or The light is configured to blink for setup. |
|
|
(1) Red PWR LED functionality is only present on some versions of the drive. |
||
Table 5-2: Troubleshooting
|
Symptom |
Possible Cause and Solution |
|---|---|
|
No Communication |
Make sure the power LED is illuminated (this indicates that power is present). |
|
Make sure that all communication cables (HyperWire, for example) are fully inserted in their ports. |