Analog Inputs [-EB1]
To interface to a single-ended, non-differential voltage source, connect the signal common of the source to the negative input and connect the analog source signal to the positive input. A floating signal source must be referenced to the analog common. Refer to Analog Input Typical Connection [-EB1].
Table: Differential Analog Input Specifications [-EB1]
Specification |
Value |
---|---|
(AI+) - (AI-) |
+10 V to -10 V (1) |
Resolution (bits) |
16 bits |
Input Impedance |
1 MΩ |
1. Signals outside of this range may damage the input |
Table: Analog Input Connector Pinout [-EB1]
Pin# | Description | In/Out/Bi |
Connector |
---|---|---|---|
1 |
+5V (250 mA max) |
Output |
|
2 |
Analog Input 1+ |
Input |
|
3 |
Analog Input 1- |
Input |
|
4 |
Analog Input 2+ |
Input |
|
5 |
Analog Input 2- |
Input |
|
6 |
Analog Input 3+ |
Input |
|
7 |
Analog Input 3- |
Input |
|
8 |
Ground |
N/A |
Table: Analog Input Mating Connector Ratings [-EB1]
Specification | Description | |
---|---|---|
Type | 8-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02397 | |
Phoenix: 1908101 | ||
Conductor Cross Section |
Solid or stranded | 20...26 AWG (0.14...0.5 mm2) |
Stranded, with ferrule, without plastic sleeve | 20...24 AWG (0.25...0.5 mm2) | |
Conductor Insulation Strip Length | 8 mm (5/16 in) | |
(1) Refer to the manufacturer website for additional information. |