Electrical Specifications
Table: Electrical Specifications (Common)
Table: Electrical Specifications (by Ordering Option)
Output Current Ordering Option | -10 | -20 | -30 |
---|---|---|---|
Motor Supply Input Current at full output power | 5 A | 10 A | 10 A |
Motor Supply Input Voltage Max(1,2) (Vrms AC1 to AC2, +10%) |
240 VAC 50/60 Hz |
||
Output Current (peak) (3) | 10 A | 20 A | 30 A |
Output Current (continuous)(3,4) | 3.5 ARMS | 5.3 ARMS | 5.3 ARMS |
Internal time delay fuse (AC1 input only) | 5 A | 10 A | 10 A |
Peak Output Voltage | 340 V | ||
Maximum Motor Supply External Breaker | 20 A maximum (Type-D) | ||
Internal Motor Supply Capacitance | 1200 µf | ||
Capacitor Safe Discharge Time (to 50 V) | 10 minutes | ||
Shunt / Brake Internal Fuse | 8 A | ||
(1) The iXC4/XC4 uses a single phase motor supply power. (2) A Lower motor supply voltage may be used. This will result in a reduction of output power. (3) There are three motor output phases from the drive. (4) These values are under full output power. Under a lighter load, the continuous output current capability will be higher. |
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.
WARNING: Electric Shock or Fire Hazard! A fault current interruption could be the result of an open branch-circuit protective device. To reduce the risk of fire or electric shock, examine the current-carrying parts and other controller components. Replace all damaged parts. If a burnout of the current element of an overload relay occurs, you must replace the complete overload relay.
AVERTISSEMENT : Risque d'électrocution ou d'incendie ! Une interruption du courant de défaut peut être provoqué par un dispositif de protection de circuit de dérivation ouvert. Pour réduire le risque d'incendie ou d'électrocution, examinez les pièces conductrices de courant et les autres composants du contrôleur. Remplacer toutes les parties endommagées. Si un grillage de l'élément de courant d'un relais de surcharge se produit, vous devez remplacer le relais de surcharge dans son ensemble.