Motor Supply Connector (-DC Option)
Motor power is applied to the DC+ and 0V terminals of the Motor Supply connector.
The DC+ input is internally connected to a 5 A fuse.
Use twisted pair wiring to minimize radiated noise emissions (refer to Minimizing Noise for EMC/CE Compliance). For inrush limiting, you must power up control and motor supply simultaneously.
Refer to Fuse Specifications for the internal fuse part numbers.
WARNING: Verify that all ground connections are installed correctly before you apply power to the iXA4/XA4.
Figure 2-3: Motor Supply Connections
Table 2-5: -DC Option Motor Supply Connector Pinout
| Pin | Description |
|---|---|
|
DC+ |
Motor Power Input (15-100 VDC) |
|
0V |
Motor Power Input Common |
|
|
Protective Earthing Conductor - 0.75 mm2 / 18 AWG min conductor size |
Table 2-6: Motor Supply Mating Connector Ratings
| Specification | Description | |
|---|---|---|
| Type | 3-Pin Terminal Block | |
| Part Numbers | Aerotech: ECK02388 | |
| Phoenix: 1756272 | ||
|
Conductor Cross Section |
One conductor, stranded with ferrule and plastic sleeve | 14...22 AWG (0.25...2.5 mm2) |
| Two conductors (same cross-section), stranded, twin ferrule with plastic sleeve | 16...20 AWG (0.5...1.5 mm2) | |
| Tightening Torque | 0.5...0.6 N·m | |
| Conductor Insulation Strip Length | 7 mm (0.25 in) | |
|
(1) Refer to the manufacturer website for additional information. |
||
Use these parameters to configure motor overload protection: AverageCurrentThreshold, AverageCurrentTime, and MaxCurrentClamp.