High-Speed Inputs
High-speed inputs 0 and 1 can be used as general purpose inputs or as the trigger signal for high speed data collection. High-speed input 1 is only available with the -AX2 or -AX4 option. Refer to the DriveDataCaptureConfigureTrigger() function topic in Automation1 Help for more information.
You can use the external PSO synchronization functions to synchronize waveform generation with an external synchronization signal. When you activate this feature, the PSO Waveform module will not generate the configured waveform when an output event is received until the rising edge of the synchronization signal occurs. Refer to the PSO Waveform Functions in Automation1 Help.
Table: High-Speed Input Specifications
Specification |
Value |
---|---|
Input Voltage |
5V - 24 V input voltages |
Input Current |
10 mA |
Input Device |
HCPL-0630 |
Delay |
50 nsec |
Table: PSO/High-Speed Input Connector
Pin# |
Description |
In/Out/Bi |
Connector |
---|---|---|---|
1 |
PSO | Output |
![]() |
2 |
Ground | Output | |
3 |
High-Speed Input 0+ | Input | |
4 | High-Speed Input 0- | Input | |
5 | High-Speed Input 1+ | Input | |
6 | High-Speed Input 1- | Input |
Table: Mating Connector Part Numbers for the PSO/High Speed Input Connector
Specification | Description | |
---|---|---|
Type | 6-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02405 | |
Phoenix: 1704755 | ||
Conductor Cross Section |
Solid or stranded | 20...26 AWG (0.14...0.5 mm2) |
Stranded, with ferrule, without plastic sleeve | 20...24 AWG (0.25...0.5 mm2) | |
Conductor Insulation Strip Length | 8 mm (5/16 in) | |
(1) Refer to the manufacturer website for additional information. |