Control Supply Connector
DANGER: Shock and Fire Hazard
Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.
The Control Supply input supplies power to the communications and logic circuitry of the
Use a control power supply that is dedicated only to the iXA4/XA4 drives to minimize noise. Do not use this supply to power other system components. Locate the power supply close to the drives.
Figure: Control Supply Connections
Table: Control Supply Connector Pinout
Pin | Description |
---|---|
+24 V |
24 VDC (±10%) Control Power Input (5 A maximum, 0.5 A typical without brake) |
0 V |
Control Power Common Input |
|
Protective Ground |
Table: Control Supply Mating Connector Ratings
Specification | Description | |
---|---|---|
Type | 3-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02456 | |
Phoenix: 1839610 | ||
Conductor Cross Section |
One conductor, stranded with ferrule and plastic sleeve | 18...22 AWG (0.25...0.75 mm2) |
Two conductors (same cross-section), stranded , twin ferrule with plastic sleeve | 20 AWG (0.5 mm2) | |
Tightening Torque | 0.22...0.25 N·m | |
Conductor Insulation Strip Length | 7 mm (0.25 in) | |
(1) Refer to the manufacturer website for additional information. |