Motor Supply Connector
DANGER: Shock and Fire Hazard!
Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.
IMPORTANT: To operate correctly, this product must have a power supply connected to the Motor Supply and a power supply connected to the Control Supply.
Motor power is applied to the XL4s at the four terminals of the Motor Supply connector. The DC+ input and the DC- input are connected to fuses inside the
DANGER: Shock Hazard! To prevent the risk of electric shock, do not operate the XL4s without a ground connection.
Figure: Motor Supply Connections
Table: Motor Supply Connector Pinout
Pin |
Description |
---|---|
DC+ | +40 VDC Input Range |
RET | Return for DC Input |
DC- | -40 VDC Input Range |
Protective Ground - 2.5 mm2 / 14 AWG min conductor size |
|
(1)The wire insulation is rated for 300 V. |
Table: Motor Supply Mating Connector Ratings
Specification | Description | |
---|---|---|
Type | 4-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02407 | |
Phoenix: 1758843 | ||
Conductor Cross Section |
One conductor, stranded with ferrule and plastic sleeve | 14...22 AWG (0.25...2.5 mm2) |
Two conductors (same cross-section), stranded, twin ferrule with plastic sleeve | 16...20 AWG (0.5...1.5 mm2) | |
Tightening Torque | 0.5...0.6 N·m | |
Conductor Insulation Strip Length | 7 mm (0.25 in) | |
(1) Refer to the manufacturer website for additional information. |