Control Supply Connector
DANGER: Shock and Fire Hazard
Electrical wiring must be designed and installed in accordance with local electrical safety regulations to prevent the risk of fire and electrical shock.
The Control Supply input supplies power to the communications and logic circuitry of the
Figure: Control Supply Connections
Table: Control Supply Connector Pinout
Pin | Description |
---|---|
+24 V |
24 VDC (±10%) Control Power Input (2-Axis: 2 A max, 0.45 A typical; 4-Axis: 2 A max, 0.6 A typical) |
0 V |
Control Power Common Input |
|
Protective Ground |
Table: Control Supply Mating Connector Ratings
Specification | Description | |
---|---|---|
Type | 3-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02456 | |
Phoenix: 1839610 | ||
Conductor Cross Section |
One conductor, stranded with ferrule and plastic sleeve | 18...22 AWG (0.25...0.75 mm2) |
Two conductors (same cross-section), stranded , twin ferrule with plastic sleeve | 20 AWG (0.5 mm2) | |
Tightening Torque | 0.22...0.25 N·m | |
Conductor Insulation Strip Length | 7 mm (0.25 in) | |
(1) Refer to the manufacturer website for additional information. |