Laser Output Connectors
The Laser Output has two 7-pin terminal block-style connectors and supplies connections to the laser control outputs. Three laser output signals are available as optically-isolated or as 5V TTL signals. You can wire the optically-isolated outputs in a sourcing or sinking configuration.
To set the active polarity of the laser output signals, use the switches on the top of the GL4. Refer to Laser Output Polarity Switches
To turn on the output and activate the laser, move the switch to the OFF position. This is the Normally-Open configuration. The laser output is fully turned on when one of these conditions occurs.
- The optically-isolated output conducts current.
- The TTL output is 5 V.
To select the opposite polarity, move the switch to the ON position. This is the Normally-Closed configuration. When the GL4 is powered off, it does not continue to support this configuration. This configuration is not a fail-safe feature.
WARNING: After you install this product, you must tell the operator about all applicable safety conditions and safety information. Refer the operator to the laser manual for safety information about the laser.
Table: Laser Output Connector A Pinout
Pin # |
Label |
Description |
In/Out/Bi |
Connector |
---|---|---|---|---|
1 |
O1+ |
Output |
|
|
2 |
O1- |
Laser Output 1- / PSO Output(1) |
Output |
|
3 |
O2+ |
Laser Output 2+ |
Output |
|
4 |
O2- |
Laser Output 2- |
Output |
|
5 |
O3+ |
Laser Output 3+ |
Output |
|
6 |
O3- |
Laser Output 3- |
Output |
|
7 |
GND |
Ground |
N/A |
|
(1) Refer to Position Synchronized Output (PSO) for more information |
Table: Laser Output Connector B Pinout
Pin # |
Label |
Description |
In/Out/Bi |
Connector |
---|---|---|---|---|
1 |
O1 |
Laser Output 1 / PSO Output (1) (5V TTL) |
Output |
|
2 | GND | Ground | N/A | |
3 |
O2 |
Laser Output 2 (5V TTL) |
Output |
|
4 | GND | Ground | N/A | |
5 |
O3 |
Laser Output 3 (5V TTL) |
Output |
|
6 |
GND |
Ground | N/A | |
7 |
+5V |
5 Volt Power Supply (500 mA) |
Output |
|
(1) Refer to Position Synchronized Output (PSO) for more information |
Table: Mating Connector Part Numbers for the Laser Output Connectors
Specification | Description | |
---|---|---|
Type | 7-Pin Terminal Block | |
Part Numbers | Aerotech: ECK02403 | |
Phoenix: 1908114 | ||
Conductor Cross Section |
Solid or stranded | 20...26 AWG (0.14...0.5 mm2) |
Stranded, with ferrule, without plastic sleeve | 20...24 AWG (0.25...0.5 mm2) | |
Conductor Insulation Strip Length | 8 mm (5/16 in) | |
(1) Refer to the manufacturer website for additional information. |
Table: Laser Output Specifications
|
Specification |
Value |
---|---|---|
Isolated Output |
Maximum Frequency |
5 MHz |
Voltage |
5 - 24 V |
|
Output Current |
≤ 50 mA |
|
5V TTL |
Maximum Frequency |
10 MHz |
Voltage |
5 V |
|
Output Current |
50 mA |
Figure: Laser Interface Outputs
Figure: Current Sinking Configuration with Isolation
Figure: Current Sinking Configuration without Isolation
Figure: Current Sourcing Configuration with Isolation
Figure: Current Sourcing Configuration without Isolation