AutofocusEncoderScaleFactor Parameter
Default Value: 1.0
Minimum Value: 0.0
Maximum Value: None
Units: Volts / Encoder Count
Type: double
HARDWARE: Autofocus does not apply when used with the GI4, the GL4, or the XL4s.
Use the AutofocusEncoderScaleFactor parameter to specify the volts per encoder count of the auxiliary feedback value. This parameter only applies if you have the AutofocusInput Parameter configured for the Auxiliary Encoder Input.