SignalLogPointsBeforeTrigger Parameter

Default Value: 4000

Minimum Value: 100

Maximum Value: None

Units: points

Type: int

IMPORTANT: You must reset the controller for these changes to have an effect. If you set this parameter from an AeroScript program, the controller does not set the active value and this parameter does not have an effect on program execution.

Use the SignalLogPointsBeforeTrigger parameter to specify the number of points that Signal Log collects before it is triggered.

When Signal Log is enabled, it continuously collects data that it stores in a circular buffer. This parameter specifies the size of the circular buffer. When Signal Log is triggered, the number of points that you specify for this parameter become available before the trigger event occurs.

Tip: This parameter requires memory allocation. If the memory allocation fails, a memory allocation error occurs. If memory resources are low, you can decrease the value of this parameter to release memory for other Automation1 features.